Christie Entero RPMWU User Manual page 169

Table of Contents

Advertisement

(HLT) PROJECTOR HEALTH
CONTROL GROUP:
DESCRIPTION
Any system health errors are placed on the troubleshooting queue. The queue, which contains the problems and a
suggested solution for each one, is read-only. All problems in the queue are read using their index number, which
starts from 0.
Problems are assigned priorities:
1 = Critical - Will result in failure to operate or shutdown
2 = High - Will result in significant loss of functionality but the projector may continue to run
3 = Low - Will result in minor loss of functionality which will not seriously affect projector
SUBCODE
LSOL
LALL
EXAMPLES:
(HLT?) - Returns all queued problems.
(HLT? 3) - Returns problem index 3 in the queue.
(HLT+LSOL? 4) - Returns the solution hint for problem index 4 in the queue.
(HLT+LALL?) - Returns all queued problems and their solutions.
(HLT+LALL? 3) - Returns problem index 3 and its' solution.
(HOR) HORIZONTAL POSITION
CONTROL GROUP:
DESCRIPTION
Move the horizontal position of the image left or right.
SUBCODE
MAIN
EXAMPLES:
(HOR 500) - Set horizontal position to 500 on main video.
(HOR+MAIN 500) - Set horizontal position to 500 on main video.
(HOR+IN32 500) - Set horizontal position to 500 on Slot 3, Input 2.
(HOR?) - Returns the horizontal position value on main video.
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
020-100367-05 Rev. 1(6-2012)
Unsaved
SUBCLASS:
Input
Power Down
SUBCLASS:
Power Down
ACCESS LEVEL:
DESCRIPTION OF USE
List solutions.
List one or all problems and solutions.
ACCESS LEVEL:
DESCRIPTION OF USE
Set the horizontal position for the main image.
Appendix D: Serial Command Reference
Operator
Operator
D-35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents