Although messages without an address are always broadcast, you can also broadcast by including the reply
destination address 65535. This ensures that replies go to a specific controller address rather than being
broadcast. The projector will also include its address.
Table C.4 - Message for Projector from a Specific Controller
If you have more than one controller on a network, ensure to include both a source address and a destination
address. With a single controller on the network, its address is never required. Place the source address
between the destination address and 3-character code, including a space before and after as shown.
Replies from a projector do not contain an address unless the request message includes both a destination
NOTE:
address and a source address—i.e., a reply to a request having only a destination address will not have any source
address.
Table C.5 - Message for Specific Projector from a Specific Controller
Examples
Command
Turn Projector #5 on.
What is the contrast level in Projector 30?
Return Contrast from Projector #30 to Controller #2.
C.3 Description Of Control Types
C.3.1 Subclasses
• Power Down Controls - These controls are accessible when the projector is in Standby power mode (i.e.
power off) as well as when powered on.
• Power Up Controls - These controls are only accessible when the system electronics are fully powered (not
necessarily lamp on).
C.3.2 Control Groups
• Unsaved Controls - These controls are not saved to flash. The settings are not maintained between power
sessions.
• Saved Controls - These controls are saved to flash. The settings are persistent between power sessions.
• Preference Controls - These controls are transferable from one projector to another. Example: NET+SUB0
(projector subnet).
• Configuration Controls - These controls are projector specific settings. They are non-transferable between
projectors. Example: NET+ETH0 (projector IP address).
• Channel Controls - These settings are specific to a particular input signal. Example: BRT (signal
brightness).
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
020-100367-05 Rev. 1 (06-2012)
(
Dest Src
Code
(
Dest
Src
Code
Message from Controller
(5pwr1)
(30con?)
(30 2con?)
Appendix C: Serial Command Overview
Data
)
Data
)
Reply from Projector
{none}
(CON!127)
(00002 00030con!127)
C-7