(CLP) CLAMPING (Cont'd)
Value Range:
0 = sync tip
1 = backporch
2 = tri-level
SUBCODE
INxy
MAIN
PIIP
EXAMPLES:
(CLP 0) - Set the black level clamping for main video to sync tip.
(CLP+MAIN 0) - Set the black level clamping for main video to sync tip.
(CLP+IN32 0) - Set the black level clamping for Slot 3 Input 2 to sync tip.
(CLR) COLOR
CONTROL GROUP:
DESCRIPTION
This control adjusts the saturation (amount) of color in a video image.
SUBCODE
INxy
MAIN
PIIP
EXAMPLES:
(CLR 500) - Set color saturation to 500 on Main video.
(CLR+MAIN 500) - Set color saturation to 500 on Main video.
(CLR+PIP 250) - Set color saturation to 250 on PIP video.
(CLR+IN32 100) - Set color saturation to 100 on Slot 3, Input 2.
(CLR ?) - Returns the current color saturation value on Main video.
(CLR+PIP ?) - Returns the current color saturation value on PIP video.
(CLR+IN12 ?) - Returns the current color saturation value on Slot 1, Input 2.
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
020-100367-05 Rev. 1(6-2012)
Input
Power Up
SUBCLASS:
Appendix D: Serial Command Reference
DESCRIPTION OF USE
Set the black level clamping for Slot x, Input y.
Set the black level clamping for main video.
Set the black level clamping for PIP video.
ACCESS LEVEL:
DESCRIPTION OF USE
Set the color saturation on Slot x, Input y to the specified value
in the range of 0-1000.
Set the color saturation on the main video to the specified
value in the range 0-1000.
Set the color saturation on the PIP video to the specified value
in the range of 0-1000.