Christie Entero RPMWU User Manual page 171

Table of Contents

Advertisement

(ITP) INTERNAL TEST PATTERN
CONTROL GROUP:
DESCRIPTION
Puts a test pattern on the screen or queries the test pattern currently displayed. Select which test pattern to
display from the list:
0 = Off
1 = Grid
2 = Grey
Scale 16
3 = White
SUBCODE
<No Subcode >
EXAMPLE:
(ITP 0) - Disable test patterns - revert to previous Input signal.
(ITP 1) - Set test pattern to the grid pattern.
(KCO) KEYSTONE CURSOR OFFSET
CONTROL GROUP:
DESCRIPTION
This control offsets the 2D Keystone cursors from the edge of the image to allow manipulation of keystone on an
overshot display.
SUBCODE
KCOT
KCOB
KCOL
KCOR
EXAMPLES:
(KCO+KCOT 25) - Offsets the cursor by 25 pixels from the top edge.
(KCO+KCOB?) - Returns the offset value in pixels from the bottom edge.
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
020-100367-05 Rev. 1(6-2012)
Unsaved
SUBCLASS:
4 = Flat Grey
5 = Black
6 = Checker
7 = 13 Point
Preference
SUBCLASS:
Power Up
ACCESS LEVEL:
8 = Color Bars
11 = Aspect Ratio
12 = Edge Blend
14 = Boresight
DESCRIPTION OF USE
Enable, disable or change standard test patterns.
Power Up
ACCESS LEVEL:
DESCRIPTION OF USE
Adjusts top offset.
Adjusts bottom offset.
Adjusts left offset.
Adjusts right offset.
Appendix D: Serial Command Reference
Operator
Operator
D-37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents