(DTL) DETAIL
CONTROL GROUP:
DESCRIPTION
This control adjusts the sharpness of the image. The sharpness detail enhancement applied is based on adaptive
horizontal, vertical and diagonal large edge and small edge enhancement processes.
Setting detail above the halfway-point can introduce 'noise' in the image; lower settings can improve a noisy
signal. This command does not take effect unless the 'minimum change required' in the (DTT) control is reached.
SUBCODE
INxy
MAIN
PIIP
EXAMPLE:
(DTL 50) - Set the detail to mid point for Main video.
(DTO) DETAIL OVERSHOOT
CONTROL GROUP:
DESCRIPTION
Detail overshoot / undershoot control is provided to minimize ringing on the enhanced edges detail and texture
effects.
SUBCODE
INxy
MAIN
PIIP
EXAMPLE:
(DTO 50) - Set the detail overshoot to mid point for Main video.
(DTT) DETAIL THRESHOLD
CONTROL GROUP:
DESCRIPTION
Detail threshold selects a filter sensitivity to noise. A higher value may improve noisy sources especially for
higher settings of detail.
This control sets the minimum change required before the detail (DTL) function is activated. This allows images
to be sharpened without increasing the background noise.
SUBCODE
INxy
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
020-100367-05 Rev. 1(6-2012)
Input
Power Down
SUBCLASS:
Input
Power Down
SUBCLASS:
Input
Power Down
SUBCLASS:
Appendix D: Serial Command Reference
ACCESS LEVEL:
DESCRIPTION OF USE
Set the detail for Slot x, Input y.
Set the detail for Main video.
Set the detail for PIP video.
ACCESS LEVEL:
DESCRIPTION OF USE
Set the detail overshoot for Slot x, Input y.
Set the detail overshoot for Main video.
Set the detail overshoot for PIP video.
ACCESS LEVEL:
DESCRIPTION OF USE
Set the detail threshold for Slot x, Input y.
Operator
Operator
Operator