Bus Commands

:BUS:B<N>:TYPE
Command
:BUS:B<N>:TYPE <protocol>
This BUS command only applies to oscilloscopes with the serial data analysis option
N O T E
installed.
The :BUS:B<N>:TYPE command sets the type of protocol being analyzed for
a serial bus waveform.
<protocol>
{CAN | DVI | FIBRechannel | E10GBASEKR | FLEXray | GEN8B10B |
GENeric | HOTLink | IIC | INFiniband | JTAG | LIN | MIPI | MPHY |
PCI3 | PCIexpress | SAS | SATA | SPI | UART | USB2 | USB3 | XAUI}
<N>
An integer, 1- 4.
Example
This example sets the serial bus waveform number one protocol type to
FLEXray.
myScope.WriteString ":BUS:B1:TYPE FLEXRAY"
Query
:BUS:B<N>:TYPE?
The :BUS:B<N>:TYPE? query returns the name of the protocol being used
for the serial bus.
Returned Format
[:BUS:B<N>:TYPE] <protocol><NL>