:ISCan:NONMonotonic:EDGE

Command
:ISCan:NONMonotonic:EDGE {EITHer | FALLing | RISing}
The :ISCan:NONMonotonic:EDGE command selects the rising edge, the
falling edge, or either edge for the Non- monotonic edge trigger mode.
EITHer
Sets the edge used by the Non- monotonic edge trigger to both rising and
falling edges.
FALLing
Sets the edge used by the Non- monotonic edge trigger to falling edges.
RISing
Sets the edge used by the Non- monotonic edge trigger to rising edges.
Example
The following example selects the falling edge non- monotonic trigger.
myScope.WriteString ":ISCAN:NONMONOTONIC:EDGE FALLING"
Query
:ISCan:NONMonotonic:EDGE?
The query returns the currently selected edge type for the Non- Monotonic
Edge trigger.
Returned Format
[:ISCan:NONMonotonic:EDGE]{EITHer | FALLing | RISing}<NL>
Example
The following example returns the currently selected edge type used for
the Non- monotonic Edge trigger mode.
Dim strSOURCE As String
myScope.WriteString ":ISCAN:NONMONOTONIC:EDGE?"
strSOURCE = myScope.ReadString
Debug.Print strSOURCE