Delta ASDA-A3 Series User Manual page 1010

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
Object 6064h: Position actual value (PUU)
Index
Name
Object code
Data type
Access
PDO mapping
Setting range
Default
Unit
Object 6065h: Following error window
Index
Name
Object code
Data type
Access
PDO mapping
Setting range
Default
Unit
Object function:
When the following error actual value (OD 60F4h) exceeds this setting range, AL009
(Excessive deviation of Position command) is triggered.
Following error
Note: when P3.012.Z is set to 1, the non-volatile setting for this object is enabled.
6064h
Position actual value
VAR
INTEGER32
RO
Yes
INTEGER32
0
PUU
6065h
Following error window
VAR
UNSIGNED32
RW
Yes
UNSIGNED32
50331648
PUU
Accepted following error
Following error
Following error
window
window
No following error
Target position
CANopen Mode
Position
Following error
12
12-61

Advertisement

Table of Contents
loading

This manual is also suitable for:

A3-lA3-mA3-fA3-e