Delta ASDA-A3 Series User Manual page 1294

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
A.3.4 Overload features
Definition of overload protection
The overload protection prevents the motor from overheating.
Causes of overload
1. The motor's operating torque exceeds the rated range and the operating time is too long.
2. The inertia ratio is too high and the motor frequently accelerates and decelerates.
3. Incorrect wiring of the power and encoder cables.
4. Incorrect servo gain setting causes resonance in the motor.
5. A motor with a built-in brake operates without the brake released.
Graph of load and operating time
220V series: low inertia (ECM-B3L series), medium inertia (ECM-B3M-C series)
400V series: medium inertia (ECM-B3M-J series)
(s)
4
10
3
10
2
10
1
10
0
10
100
Load ratio
Operating time
Load ratio
Operating time
150
200
250
120%
140%
263.8 s
35.2 s
17.6 s
260%
280%
3.9 s
3.3 s
300
350
160%
180%
200%
11.2 s
300%
350%
400%
2.8 s
2.1 s
1.6 s
Specifications
(%)
400
450
500
220%
240%
8 s
6.1 s
4.8 s
450%
500%
1.2 s
1.0 s
A
A-57

Advertisement

Table of Contents
loading

This manual is also suitable for:

A3-lA3-mA3-fA3-e

Table of Contents