AL257 Second development platform - the system object function block ID is out of range
when the object is used
Checking method
and corrective action
How to clear the
alarm?
AL25B Second development platform - object argument format error
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
AL25F Second development platform - an error occurred when the object dictionary is
accessed
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
AL261 Second development platform - commands dedicated for the master cannot be used
when the master mode is not enabled
Trigger condition
and cause
Refer to the command descriptions for the second development platform to
1.
ensure the correct use of the commands.
Check if you are using the latest version of the EzASD software.
2.
If you took the corrective actions but the issue persists, contact the local distributor
or technician.
DI.ARST
Condition: when the system object is used, the argument format of the object is in
error.
Cause:
Incorrect use of the command of the second development platform.
1.
The EzASD software version and the firmware version do not match.
2.
Refer to the command descriptions for the second development platform to ensure
the correct use of the commands. If you took the corrective action but the issue
persists, contact the local distributor or technician.
DI.ARST
Condition: when an object dictionary command is used, an error occurred because
the value is out of range or the object dictionary does not exist.
Cause: when the object dictionary is accessed, the value of the object dictionary is
out of range or the firmware does not support the object dictionary.
Check if the setting for this object dictionary in the program is correct.
If you took the corrective action but the issue persists, contact the local distributor
or technician.
DI.ARST
Condition: when the servo drive is in Modbus slave mode (P3.005.Y = 0),
a command dedicated for the master is used.
Cause: master mode is not enabled.