ALD24 EnDat 2.2 encoder - temperature warning
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
ALD25 EnDat 2.2 encoder - sensor signal strength warning
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
Condition: an error occurred to the EnDat 2.2 encoder.
Cause:
The installation or wiring of the encoder is incorrect.
1.
The installation and operating environment do not meet the specifications,
2.
causing encoder error.
The encoder is damaged.
3.
Make sure the encoder or read head is correctly installed and wired according
1.
to the manufacturer's instruction manual.
If the issue persists, contact the distributor of the encoder.
2.
DI.ARST or cycle power on the servo drive.
Condition: an error occurred to the EnDat 2.2 encoder.
Cause:
The installation or wiring of the encoder is incorrect.
1.
The installation and operating environment do not meet the specifications,
2.
causing encoder error.
The encoder is damaged.
3.
Make sure the encoder or read head is correctly installed and wired according
1.
to the manufacturer's instruction manual.
If the issue persists, contact the distributor of the encoder.
2.
DI.ARST or cycle power on the servo drive.