ASDA-A3
EtherCAT error indicator (ERR)
Indicator
Steady off
Steady on
Continuous flashing
Single flashing
Status
No error
PDI Watchdog timeout
State change error
Synchronization error /
SyncManager error
Figure 13.1.1.1 State transition diagram
Description
No error has occurred.
Servo drive malfunction. Contact Delta's
distributor for assistance.
Parameter setting error causes the system unable
to switch states. Refer to Figure 13.1.1.1.
The synchronization between the controller and
the servo drive failed or the data was lost during
data reception.
EtherCAT Mode