5.6

Attaching the LRM to the MEM

To attach the LRM to the MEM, follow these steps:
1.
On the side of the MEM closest to the LRM, locate the two alignment holes at the
top and bottom.
2.
Insert the narrow end of a bullet-nose alignment pin into each hole. See
Figure
Figure 5-13 Inserting an alignment pin into the MEM (upper hole shown)
3.
Confirm that the pins on the MEM align with the holes on the LRM.
Important:
4.
Push the MEM against the LRM and guide the bullet-nose ends of the alignment
pins into the corresponding holes on the LRM.
5.
Locate the three holes on the back of the LRM frame that are used to secure the
LRM to the MEM.
6.
Open the doors of the MEM and the LRM to access the three holes in the front.
XLS Library Installation Manual
5-13.
Bullet-nose
alignment pin
If the pins do not align with the holes, adjust the
leveling feet on the MEM (see
page
5-12).