14.2 Scanning and Calibrating the Fiducials

14.2
Scanning and Calibrating the Fiducials
Important:
Once you have installed the cartridges, you are ready to scan and calibrate the location of
each I/O port, cartridge slot, and tape drive. When you perform a fidicual scan, the XLS
moves the handler to each cartridge magazine and I/O port and attempts to locate the
fiducial targets, shown in
Fiducial
Figure 14-1 Cartridge magazine with two fiducials
It also inserts the calibration cartridge, stored in slot G50, into each tape drive to
precisely locate the tape drive's position.
To scan and calibrate the fiducials, follow these steps:
1.
If necessary, apply power to the library and log in to X-Link. See
on page
2.
If necessary, press the Home button in the upper right corner of any page to
return to the Home page.
14-2
A fiducial scan is only required if performing an
upgrade to the library. Upgrades include the addition of
drive bays, door slots, I/O Ports, and/or expansion
modules (MEM or POD) to the library. Installation of
single LRM units do not require a Fiducial scan.
Figure
14-1.
10-3.
Fiducial
Section 10.2
501601 Rev. 07-01-19