Qualstar XLS Series Installation Manual page 186

Tape libraries
Hide thumbs Also See for XLS Series:
Table of Contents

Advertisement

11.6 Defining Other Library Settings and Policies
Events are deleted in first-in first-out (FIFO) sequence; that is, the oldest events are
deleted first.
To view or edit event log settings, follow these steps:
1.
Access the Settings & Policies portlet as described in
11-36.
2.
Select View/Edit Event Log Settings. The View/Edit Event Log Settings page
opens, as shown in
Figure 11-35 View/Edit Event Log Settings page
3.
In the Maximum # of events to save field, enter the maximum number of
events you want to save in the event log. The library can save a maximum of
1,000 events. As soon as there are more events in the log than this number, the
library deletes the oldest event.
4.
In the Save events for field, enter the number of hours, days, or weeks to save
events for. Then, select hours, days, or weeks from the drop-down list. As soon
as there are events in the log older than this age, the library deletes them.
5.
Press Save Changes to save the information.
11.6.5 Viewing and Editing Library Policies
This section describes how to view and edit policies for the physical library. The library
uses these settings to determine the following:
• When to send alerts that the library's air filters need to be checked
• When to log off idle users
• What severity of events to e-mail or page users about
To view or edit policy settings for the physical library, follow these steps:
1.
Access the Settings & Policies portlet as described in
11-36.
11-40
Figure
11-35.
Section 11.6.1 on page
Section 11.6.1 on page