Cause of error...
Inadequate number of power
supplies or power supplies not
installed correctly
Carousel unable to move
Inner hard stop on handler's
X-axis not removed
Battery module not charged
Table 10-1 Initial troubleshooting steps for power-on error (continued)
4.
If the error persists, contact Qualstar Technical Support for assistance.
10.2.2 Meanings of the LEDs
This section describes the status LEDs on the library's front panel, on the tape drive
assemblies, and on the power supplies.
Front Panel LEDs
Figure 10-7
Figure 10-7 Status LEDs on the LRM front panel
XLS Library Installation Manual
Check this...
If the library failed to power up correctly, you may not have
enough power supplies for the number of installed drive bays
and MEMs.
If you are using one or more MEMs and the carousel did not
rotate, confirm the following:
• The carousel controller cable is attached correctly
• The carousel locks have been released
• Nothing is blocking the carousel
If you are using one or more MEMs, make sure that the inner
hard stop on the handler's X-axis has been removed, allowing the
handler to reach into the MEM.
If the Charge LED on the battery module is illuminated, the
battery module may not be fully charged. It can take up to 10
minutes for the battery to fully charge.
shows the status LEDs on the front panel of the LRM.