Qualstar XLS Series Installation Manual page 27

Tape libraries
Hide thumbs Also See for XLS Series:
Table of Contents

Advertisement

The curtain of light formed by the emitters and detectors allows the XLS to precisely
monitor all areas within the LRM and MEM cabinets, as follows:
• The beams of light at the rear of the cabinet can detect whether a cartridge is
protruding from a slot. If the door(s) are closed and one of these beams of light is
broken, the XLS prevents the handler from moving to avoid hitting a protruding
cartridge.
• The beams of light curtain at the front of the cabinet can detect when someone
reaches into the cabinet. If a door is open and one of these beams of light is
broken, the XLS detects and logs a potential inventory violation and
automatically scans the cartridges and drives in the affected area as soon as all
doors are closed.
1.2.8
Equipment Rack
Shown in
Figure
optional EIA 19-inch equipment rack installed in a vertical orientation (equipment
installed on its side). The rack can accommodate equipment up to 26 inches deep (66 cm).
Installed equipment could include a Fibre Channel switch or other ancillary equipment.
Two versions of the rack option are available. The 6U rack (10.5-inches) resides entirely
within the LRM cabinet. The 8U (14-inches) rack protrudes 3.5 inches beyond the rear of
the LRM cabinet. A 15-amp power strip with six grounded outlets and circuit breaker is
supplied with either equipment rack. This power strip must be connected to an external
power source.
Figure 1-20 Equipment rack option (6U rack shown in XLS-832700)
XLS Library Installation Manual
1-20, the LRM (excluding 8161100) provides space in the back for an
1
About This Manual
1-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xls-8161100Xls-832700Xls-820500Xls-812300

Table of Contents