8.17.2. Health Status Tab
1 2 3
4 5
6
Health Status tab in the Diagnostics menu
The actual temperature, voltage, fan, dark mode and control lock status of the endpoint devices can be
overviewed in the Link Status tab. The details of the listed information are the following:
#darkmode #controllock #health #new
1
Action buttons
Identify the device: clicking on the icon makes the four front panel LEDs
blink in green for 10 seconds. The feature helps to
identify the device itself in the rack shelf.
Restart the device: clicking on the icon makes restarting the endpoint.
2
Logical device
Logical device ID means the MMU assigns a number to the endpoints ordered
ID (endpoint
by the discovery. For example the first endpoint gets the 1 (appears as X1), the
number)
second one the 2 (appears as X2).
The listed endpoint devices can be sorted by clicking on the
Device name
3
The name of device which is composed of the UBEX word and the last six
characters of the MAC address.
The listed endpoint devices can be sorted by clicking on the
4
Operation Mode
The current operation mode of the endpoint device (transmitter / receiver /
transceiver). The operation mode can be changed in the drop-down menu. This
operation requires restarting the device.
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
series – Matrix Application Mode – User's Manual
series – Matrix Application Mode – User's Manual
7 8
9
q
w
#systemmonitor
icon.
icon.
Label
5
e r
6
Aggregated BW
7
System
Temperature
8
Voltage
9
Fan #1 / Fan #2
q
Uptime
w
Dark Mode
e
Control Lock
r
Filters
The device label. It can be changed by the user. See the details in the
Information
section in case of the TX or TRX operation modes and in the
Device Information
section in case of RX or TRX operation modes.
The listed endpoint devices can be sorted by clicking on the
The aggregated bandwidth which are used by the endpoint device. It can be
10.00 Gbps (in case of only one SFP+ port is used) or 20.00 Gbps (in case of both
SFP+ ports are used).
System temperature of the endpoint device displayed in Celsius degrees.
The values are the following:
Under 84 °C - OK
Between 85 °C and 89 °C -
Warning
Above 90 °C -
Error
Voltage status. Three possible values can be displayed: OK; Warning; Error.
In case ERROR value please power off the device immediately.
Actual RPM (revolution per minute) value of the fan #1 and #2.
Uptime of the endpoint device.
The dark mode feature can be enabled or disabled. It keeps the LCD screen
and the LEDs unlit to hide the device during the event when the settings is
enabled.
Enable/disable the operation of the jog dial control knob.
Applying filters help to find the required endpoint devices for checking in case
of a larger UBEX matrix. The function contains the following filter categories:
Operation Mode
– Transmitters
– Receivers
– Transceivers
Aggregated Bandwidth
– Offline
– 10G
– 20G
123
123
Device
icon.