9.6.14. Restarting the Device
Calling the method results the endpoint restarts – the connection with the remote device and the signal
transmission will be terminated. After rebooting the configuration settings are reloaded and the connection
with the remote device is established again.
Command and Response
#restart #reboot #reset
ç CALL•/SYS/ENDPOINTS/<UBEX_EP>:reset()
æ mO•/SYS/ENDPOINTS/<UBEX_EP>:reset=
Example
ç CALL /SYS/ENDPOINTS/UBEX0039A1:reset()
æ mO /SYS/ENDPOINTS/UBEX0039A1:reset=
9.6.15. Restore the Factory Default Settings
Command and Response
#factory
ç CALL•/SYS/ENDPOINTS/<UBEX_EP>:factoryDefaults()
æ mO•/SYS/ENDPOINTS/<UBEX_EP>:factoryDefaults=
Example
ç CALL /SYS/ENDPOINTS/UBEX0039A1:factoryDefaults()
æ mO /SYS/ENDPOINTS/UBEX0039A1:factoryDefaults=
The device is restarted, current connections are terminated, and the default settings are restored. See the
complete list in the
Factory Default Settings
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
series – Matrix Application Mode – User's Manual
series – Matrix Application Mode – User's Manual
section.
9.7. Endpoint Management Commands
Parameters
#endpointmanagement
Parameter
Description
<UBEX_EP>
UBEX endpoint ID
9.7.1. Query the Number of Registered Endpoints
The query returns with the number of registered endpoints (transmitters, receivers, and transceivers together)
in the UBEX matrix. This number contains all endpoints which had been registered once by the MMU.
Command and Response
ç GET•/SYS/ENDPOINTS.RegisteredEndpoints
pr•/SYS/ENDPOINTS.RegisteredEndpoints=<number>
æ
Example
ç GET /SYS/ENDPOINTS.RegisteredEndpoints
æ pr /SYS/ENDPOINTS.RegisteredEndpoints=45
9.7.2. Query the Number of Connected Endpoints
The query returns with the number of the currently connected endpoints (transmitters, receivers, and
transceivers together) in the UBEX matrix.
Command and Response
ç GET•/SYS/ENDPOINTS.ConnectedEndpoints
pr•/SYS/ENDPOINTS.ConnectedEndpoints=<number>
æ
Example
ç GET /SYS/ENDPOINTS.ConnectedEndpoints
æ pr /SYS/ENDPOINTS.ConnectedEndpoints=44
9.7.3. Query the Number of Registered Transmitters
The query returns with the number of registered transmitters in the UBEX matrix. This number contains all
transmitters which had been registered once by the MMU.
Command and Response
ç GET•/SYS/ENDPOINTS.RegisteredTxEndpoints
pr•/SYS/ENDPOINTS.RegisteredTxEndpoints=<number>
æ
Example
ç GET /SYS/ENDPOINTS.RegisteredTxEndpoints
æ pr /SYS/ENDPOINTS.RegisteredTxEndpoints=16