8. Software Control - Lightware Device Controller
8. Software Control - Lightware Device Controller
8.16.3. System Log Tab
System log tab in the MMU settings menu
All UBEX matrix related notifications are listed in the System log tab which are grouped in four categories:
info, notice, warning, and error. The categories are summerized on the right side of the tab in the Summary
section. The list can be costumized by the Column Switchers by turning on or off the following columns: Time,
Level, Identification, and Message.
All system log tracks can be saved to the control computer with the Export full system log button.

INFO:
Please always download the system logs and send to the Lightware Support Team
(support@lightware.com) for the most effective collaboration in the case of a troubleshooting issue.
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
series – Matrix Application Mode – User's Manual
series – Matrix Application Mode – User's Manual
8.16.4. System Tab
The following functions are available under System tab:
Factory defaults - recalling factory defaults settings and values for the MMU. All factory default settings
are listed in the
Download backup and diagnostics - saving the configuration backup file and the diagnostic information of
the device. See the contents of the backup file in the
Reboot device
– Quick reset: the controller software of the MMU reboots, but the hardware of the unit does not
reboot.
– Reboot: the MMU reboots, it is the same like disconnecting the power source and reconnecting
again.
#log
INFO:

The video signal transmission is not affected by any kind of rebooting of the MMU.
Restore system settings - select a backup file of the MMU on your computer and select the Restore button
to load it. The configuration settings saved in the file are applied immediately.
Date / time settings - two options are available to set the date and time:
– Set current date / time - system time can be set manually or can be synchronized with your control
device.
– NTP settings: an NTP server address can be set and enable/disable the service to synchronize the
date and time.
DEFINITION:

between computer systems over packet-switched, variable-latency data networks.
System tab in the MMU settings menu
UBEX-MMU-X200
section.
#factory
Content of Backup File
#softreset
#reboot #restart #reset
#time #date
#ntp
The Network Time Protocol (NTP) is a networking protocol for clock synchronization