9. Programmer's Reference
9. Programmer's Reference
9.7.4. Query the Number of Connected Transmitters
The query returns with the number of the currently connected transmitters in the UBEX matrix.
Command and Response
ç GET•/SYS/ENDPOINTS.ConnectedTxEndpoints
pr•/SYS/ENDPOINTS.ConnectedTxEndpoints=<number>
æ
Example
ç GET /SYS/ENDPOINTS.ConnectedTxEndpoints
æ pr /SYS/ENDPOINTS.ConnectedTxEndpoints=13
9.7.5. Query the Number of Registered Receivers
The query returns with the number of registered receivers in the UBEX matrix. This number contains all
receivers which had been registered once by the MMU.
Command and Response
ç GET•/SYS/ENDPOINTS.RegisteredRxEndpoints
pr•/SYS/ENDPOINTS.RegisteredRxEndpoints=<number>
æ
Example
ç GET /SYS/ENDPOINTS.RegisteredRxEndpoints
æ pr /SYS/ENDPOINTS.RegisteredRxEndpoints=28
9.7.6. Query the Number of Connected Receivers
The query returns with the number of the currently connected receivers in the UBEX matrix.
Command and Response
ç GET•/SYS/ENDPOINTS.ConnectedRxEndpoints
pr•/SYS/ENDPOINTS.ConnectedRxEndpoints=<number>
æ
Example
ç GET /SYS/ENDPOINTS.ConnectedRxEndpoints
æ pr /SYS/ENDPOINTS.ConnectedRxEndpoints=25
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
series – Matrix Application Mode – User's Manual
series – Matrix Application Mode – User's Manual
9.7.7. Query the Number of Registered Transceivers
The query returns with the number of registered transceivers in the UBEX matrix. This number contains all
receivers which had been registered once by the MMU.
Command and Response
ç GET•/SYS/ENDPOINTS.RegisteredTrxEndpoints
pr•/SYS/ENDPOINTS.RegisteredTrxEndpoints=<number>
æ
Example
ç GET /SYS/ENDPOINTS.RegisteredTrxEndpoints
æ pr /SYS/ENDPOINTS.RegisteredTrxEndpoints=28
9.7.8. Query the Number of Connected Transceivers
The query returns with the number of the currently connected transceivers in the UBEX matrix.
Command and Response
ç GET•/SYS/ENDPOINTS.ConnectedTrxEndpoints
pr•/SYS/ENDPOINTS.ConnectedTrxEndpoints=<number>
æ
Example
ç GET /SYS/ENDPOINTS.ConnectedTrxEndpoints
æ pr /SYS/ENDPOINTS.ConnectedTrxEndpoints=25
9.7.9. Query the Connection Status of an Endpoint
Command and Response
ç GET•/SYS/ENDPOINTS/<UBEX_EP>.ConnectionStatus
pr•/SYS/ENDPOINTS/<UBEX_EP>.ConnectionStatus=<status>
æ
Parameters
Parameter
<status>
Example
ç GET /SYS/ENDPOINTS/UBEX0039A1.ConnectionStatus
æ pr /SYS/ENDPOINTS/UBEX0039A1.ConnectionStatus=Online
Parameter description
Value
The device powered off or not
Offline
connected to the UBEX matrix.
Connection status of
The device is establishing connection
Connecting
the selected endpoint
to the UBEX matrix.
The device is powered on and ready
Online
to use in the UBEX matrix.
141
141
Value description