Front And Rear View - F-Series Endpoint Devices; Front View - Lightware UBEX-MMU-X200 User Manual

Av over ip multimedia extender
Hide thumbs Also See for UBEX-MMU-X200:
Table of Contents

Advertisement

 
 
2. Product Overview
2. Product Overview
2.1. Front and Rear View - F-series Endpoint Devices
2.1.1. Front View
All Models
1
Status LEDs
The LEDs give immediate feedback about the current status of the endpoint
device. See the details about the operation of the LEDs in the
section (on the right side).
LCD screen
LCD screen showing the most important settings and parameters in the front
2
panel menu. The available settings and information depends on the current
application mode. See the details in the
Endpoints
Jog dial control
Easy setting and menu navigation by the jog dial control. Keep dialing and
3
knob
click while getting feedback on the LCD.
The operation of the jog dial control knob can be disabled by the control lock
feature. The function can be enabled by the following methods:
Lightware Device Controller (LDC) software / Built-in website - see the
details in the
LW3 protocol command - see the details in the
4
Reset button
Reboots the device (the same as disconnecting from the power source and
reconnecting again).
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
1
2
3
Front Panel LCD Menu Operation -
chapter.
Health Status Tab
section;
Control Lock
series – Matrix Application Mode – User's Manual
series – Matrix Application Mode – User's Manual
Status LEDs
LIVE
blinking The device is powered and ready to use.
off
4
STATUS
on
blinking Measured temperature or voltage value is out of the limits.
off
LINK OK
on
Status LEDs
blinking
off
MMU AVAILABLE
on
blinking Matrix mode is active; no communication between the endpoint and the MMU.
off
#new
Dark Mode
Rental application requires this function, which keeps the LCD screen and the LEDs unlit to hide the device
during the event. The function can be enabled by the following methods:
section.
Front panel LCD menu - see the details in the
Lightware Device Controller (LDC) software / Built-in website - see the details in the
section;
LW3 protocol command - see the details in the
The device is not powered or out of operation.
All measured temperature and voltage values are within the limits.
The device is not powered or out of operation.
The connection is established on the fiber optical links and the Link Aggregation is
working.
The connection is established on the fiber optical links and LACP detection period is
active.
No connection is established on one of the fiber optical links.
Matrix mode is active; the communication is live between the endpoint and the Matrix
Management Unit (MMU).
Extender mode is active; no communication between the endpoint and the MMU.
Front Panel
section;
Dark Mode Setting
20
20
Transmitter / Receiver / Transceiver
Transmitter / Receiver / Transceiver
Transmitter / Receiver / Transceiver
Transmitter / Receiver / Transceiver
#new
Health Status Tab
section.

Advertisement

Table of Contents
loading

Table of Contents