9. Programmer's Reference
9. Programmer's Reference
9.16.14. Query the Health Status of a Selected Endpoint
The query returns with all health related information about the selected enpoint device.
#systemmonitor #new
Command and Response
ç GETALL•/SYS/ENDPOINTS/<UBEX_EP>/STATUS/HEALTH
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/HEALTH.OverallHealthState=<status>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/HEALTH.TemperatureState=<status>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/HEALTH.VoltageState=<status>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/HEALTH.VeryHighTemperatureOperation=<logical_value>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/HEALTH.UpTime=<second>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/HEALTH.SystemTemperature=<temperature>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/HEALTH.Fan1=<fan_status>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/HEALTH.Fan2=<fan_status>
Example
ç GETALL /SYS/ENDPOINTS/UBEX0039A1/STATUS/HEALTH
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/HEALTH.OverallHealthState=OK
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/HEALTH.TemperatureState=OK
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/HEALTH.VoltageState=OK
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/HEALTH.VeryHighTemperatureOperation=1
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/HEALTH.UpTime=9948
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/HEALTH.SystemTemperature=79 C; 0;85; 0;89;26;82;
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/HEALTH.Fan1=0;2;818
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/HEALTH.Fan2=0;2;886
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
series – Matrix Application Mode – User's Manual
series – Matrix Application Mode – User's Manual
9.16.15. Query the Link Status of a Selected Endpoint
#health
The query returns with all SFP+ link related information about the selected enpoint device.
#new
Command and Response
GETALL•/SYS/ENDPOINTS/<UBEX_EP>/STATUS/UPLINK/<link>
ç
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/UPLINK/<link>.LinkState=<status>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/UPLINK/<link>.TxBandwidth=<bandwidth>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/UPLINK/<link>.RxBandwidth=<bandwidth>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/UPLINK/<link>.Uptime=<second>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/UPLINK/<link>.PacketErrorRatio=<packet_error_ratio>
æ pr
/SYS/ENDPOINTS/<UBEX_EP>/STATUS/UPLINK/<link>.SignalQuality=<percent>
Example
ç GETALL /SYS/ENDPOINTS/UBEX0039A1/STATUS/UPLINK/LINK1
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/UPLINK/LINK1.LinkState=Up
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/UPLINK/LINK1.TxBandwidth=7.90
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/UPLINK/LINK1.RxBandwidth=0.00
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/UPLINK/LINK1.Uptime=807
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/UPLINK/LINK1.PacketErrorRatio=0.00
æ pr /SYS/ENDPOINTS/UBEX0039A1/STATUS/UPLINK/LINK1.SignalQuality=100