8. Software Control - Lightware Device Controller
8. Software Control - Lightware Device Controller
8.11.3. Transceiver Operation Mode
HDMI Out 1 Panel
Clicking on the HDMI out 1 panel opens the properties of the output port. The most important signal
information and settings are available from the panel.
Endpoint tab of the Device properties window - Transceiver - Output port properties
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
series – Matrix Application Mode – User's Manual
series – Matrix Application Mode – User's Manual
Settings
HDCP mode:
– Depends on input: the level and version of HDCP-encryption depends on the source device;
– Maximum possible: the output ports set the maximum HDCP-encryption level which can accept by
the connected sink device.
– Forced HDCP 2.2 Type 1: the output ports always force HDCP 2.2 Type 1. If the sink device supports
this HDCP-encryption level, the signal will be encrypted with HDCP 2.2 Type 0/1. The signal will be
encrypted with HDCP 2.2 Type 1 when the source and the sink either support this HDCP-encryption level.
Power 5V mode (Auto / Always on / Always off);
Timing mode (Free run / Source locked);
ATTENTION!

as fallback, an
Pass-through mode or the resolution of the source stream is not the same that the destination stream's
one.
Identify Stream / Identify
Scaler Settings
Scaling mode:
– Passthrough: the scaler is in pass-through mode.
– Forced resolution: the scaling is active, the selected value in the forced resolution option will be
applied on the video signal;
– EDID based: the scaler forces the resolution which is read out from the EDID of the connected sink
device.
Forced resolution: list of the available resolutions with refresh rate values. The selected one will be
applied on the video signal. See the available resolution in the
EDID based resolution: the resolution which is read out from the EDID of the connected sink device.
Image position (Stretch / Fit / Center);
Color space conversion (No conversion / RGB / YCbCr 4:4:4 / YCbCr 4:2:2);
Color range (No conversion / Full range / Limited range);
No Sync Screen (Test
Signal freeze button: the signal freezes at the last video frame on the sink device (the sink may show a
broken frame either).
Status / Signal Info
All important information (e.g. hotplug detect, HDCP status, resolution, total size, pixel clock, color space,
e.g.) are available in the status and signal info sections.
Display Info
All related information about the sink device connected to the output port.
#scaler #csc #colorspace #colorrange #testpattern #nosyncscreen
#hdcp #new
#power5v
#timingmode #freerun #sourcelocked
When the Source locked mode setting was unsuccessful and the port uses Free run mode
icon appears beside the settings. It may causes that the scaler / FRC setting is not in
Display.
#identifystream #identifydisplay
#new
Pattern);
#new
107
107
Resolutions of the Scaler / FRC
section.