Ubex-Mmu-X200; Content Of Backup File; Control Port Numbering Of The Mmu - Lightware UBEX-MMU-X200 User Manual

Av over ip multimedia extender
Hide thumbs Also See for UBEX-MMU-X200:
Table of Contents

Advertisement

 
 
14. Appendix
14. Appendix
14.2.3. UBEX-MMU-X200
Parameter
IP address
Subnet mask
Static gateway
DHCP
LW3 port number
Configuration
UBEX matrix database, including:
Database of claimed endpoints;
Crosspoint settings;
Stream names;
Device names;
Tags;
Port properties;
Scaler / FRC / CSC / Color range settings;
Video wall configuration.
14.3. Content of Backup File
The backup file contains numerous settings and parameters saved from the device. When the file is uploaded
to a device, the followings will be overwritten.
INFO:

The configuration settings of the endpoint devices are stored in the MMU in Matrix application
mode.
For the procedure of the backup and restore function see the details in the
Device label
NTP mode, NTP server address
Endpoint management settings
List of the claimed endpoints
Operation mode of the endpoints
Device assignments
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
Setting/Value
Network settings
192.168.0.100
255.255.255.0
192.168.0.1
Disabled
6107
RS-232 port configuration
BAUD 115200 8N1
UBEX matrix
Cleared
System Tab
section.
General
series – Matrix Application Mode – User's Manual
series – Matrix Application Mode – User's Manual
Video stream connection states, Audio stream connection states
Source MUX settings
Stream names, Tags, Icons
HDCP setting
Scaler enable/disable status, Resolution setting, Image position
Frame rate converter enable/disable status, Resolution setting
Color space conversion setting
Stream names, Tags, Icons
HDCP mode, Power +5V mode, Color depth setting
Scaler enable/disable status, Resolution setting, Image position
Frame rate converter enable/disable status, Resolution setting
Color space conversion setting; Color range setting
No sync screen mode, No sync screen color
All video wall related settings
User EDID data, Emulated EDIDs by ports, Dynamic EDID data
MMU control ports: Name, Mode
Endpoint control ports: Name, Mode
MMU: Baudrate, Databits, Stopbits, Parity
Endpoints: Baudrate, Stopbits, Parity, Port name
14.4. Control Port Numbering of the MMU
Serial control ports
Crosspoint settings
Stream source settings
Destination port settings
Video wall settings
EDID management settings
Ethernet port settings
Serial port configuration
Description
RS-232 1
RS-232 2
233
233
Port number
P1
P2

Advertisement

Table of Contents
loading