System Commands - Mmu; Set The Device Label; Query The Product Name; Query The Firmware Package Version - Lightware UBEX-MMU-X200 User Manual

Av over ip multimedia extender
Hide thumbs Also See for UBEX-MMU-X200:
Table of Contents

Advertisement

 
 
9. Programmer's Reference
9. Programmer's Reference
9.5. System Commands - MMU
9.5.1. Set the Device Label
INFO:

The device label can be changed to a custom text in the
The Device Label can be 39 characters long and ASCII characters are allowed. Longer names will be
truncated.
Command and Response
#label #devicelabel
SET•/MANAGEMENT/LABEL.DeviceLabel=<custom_name>
ç
pw•/MANAGEMENT/LABEL.DeviceLabel=<custom_name>
æ
Example
ç SET /MANAGEMENT/LABEL.DeviceLabel=MMU_ServerRoom
æ pw /MANAGEMENT/LABEL.DeviceLabel=MMU_ServerRoom
9.5.2. Query the Product Name
ATTENTION!

The name of the product is a read-only parameter and cannot be modified.
Command and Response
ç GET•/.ProductName
pr•/.ProductName=<Product_name>
æ
Example
ç GET /.ProductName
æ pr /.ProductName=UBEX-MMU-X200
9.5.3. Query the Firmware Package Version
Command and Response
#firmwareversion
ç GET•/MANAGEMENT/UID/PACKAGE.Version
pr•/MANAGEMENT/UID/PACKAGE.Version=<firmware_version>
æ
Example
ç GET /MANAGEMENT/UID/PACKAGE.Version
æ pr /MANAGEMENT/UID/PACKAGE.Version=v1.3.0b6
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
series – Matrix Application Mode – User's Manual
series – Matrix Application Mode – User's Manual
Status Tab
of the LDC software.
9.5.4. Query the Date and Time of the System
The query returns with the current date and time which is set in the MMU. The format is based on the
ISO 8601 standard.
Command and Response
#time #date
ç GET•/MANAGEMENT/DATETIME.CurrentTime
pr•/MANAGEMENT/DATETIME.CurrentTime=<date_time>
æ
Parameters
Parameter
Description
<date_time>
Current date and time
Example
ç GET /MANAGEMENT/DATETIME.CurrentTime
æ pr /MANAGEMENT/DATETIME.CurrentTime=2019-11-30T06:23:37
9.5.5. Setting of the Date and Time Manually
The date and time format is based on the ISO 8601 standard.
Command and Response
CALL•/MANAGEMENT/DATETIME:setTime=<date_time>
ç
æ mO•/MANAGEMENT/DATETIME:setTime=
Parameters
See at previous section.
Example
ç CALL /MANAGEMENT/DATETIME:setTime=2019-12-24T20:00:15
æ mO /MANAGEMENT/DATETIME.setTime=
9.5.6. Setting the NTP Server
DEFINITION:

The Network Time Protocol (NTP) is a networking protocol for clock synchronization
between computer systems over packet-switched, variable-latency data networks.
Command and Response
#ntp
SET•/MANAGEMENT/DATETIME.NtpServerAddress=<server_address>
ç
pw•/MANAGEMENT/DATETIME.NtpServerAddress=<server_address>
æ
Example
ç SET /MANAGEMENT/DATETIME.NtpServerAddress=pool.ntp.org
æ pw /MANAGEMENT/DATETIME.NtpServerAddress=pool.ntp.org
135
135
Formula
YYYY-MM-DDTHH:MM:SS

Advertisement

Table of Contents
loading

Table of Contents