4.8.3 Power-Up Sequence (PLL)

The standby signal (STBY) to the PLL is an extension of XRESET by ca. 2.5 µsec.

4.8.4 PLL Behavior

4.8.4.1 following crystal break

If the ext. crystal breaks, i.e. CLK_A, CLK_B are
open
clamped to '0'
clamped to '1',
a frequency of 100 MHz ... 300 MHz is established at the PLL output (free-running fre-
quency).

4.8.4.2 upon temporary clock failure

The period jitter is considerably less than 50 ps and is therefore within the specified range
provided the recommended filter connections for AVDD decoupling are used.
If the reference clock for the ERTEC 200P PLL fails, the frequency changes continuously
until it reaches the final value after ca. 30 µs.