Bit
Identifier
31dt0 EXT_EVENT_1_VALUE
Register:
TIM_2_EXT_EV_2_REG
Bits:
31dt0
Description:
Bit
Identifier
31dt0 EXT_EVENT_2_VALUE
Register:
TIM_3_MODE_REG
Bits:
31dt0
Description:
Bit
Identifier
0
INIT_BIT
3dt1
<reserved>
4
CLK_INPUT_SELECT
5
RELOAD_DISABLE
6
DIS_RLD_WHEN_WR_LDREG 0h
7
EXT_GATE_TRIG_ENABLE
8
GATE_POLARITY
9
GATE_EFFECT
Copyright © Siemens AG 2016. All rights reserved
Technical data subject to change
Timer EXT_EVENT_1 Register for Timer 2
Reset
00000000h rh w External Event 1 Value
Reset value:
Timer EXT_EVENT_2 Register for Timer 2
Reset
00000000h rh w External Event 2 Value
Reset value:
Timer Mode Register for Timer 3
Reset
0h
0h
0h
0h
0h
0h
0h
293
Attr.
Function / Description
00000000h
Attr.
Function / Description
00000000h
Attr.
Function / Description
Initialization (0 =INIT_BIT not active,
w
1 =INIT_BIT active)
not used
Selection of Count-/Load-Clock
0 =CLK_TIMT, 1 =ext. Gate-
r
w
/Triggersignal, see also bit
GATE_EFFECT)
Reload Mode disable
r
w
0 =Reload Mode is active, 1 =Single
Mode is active
Disable Reload when Writimg Load-
Register
r
w
0 =Reload Mode is active, 1 =Single
Mode is active
Selection of Gate-/Trigger signal
0 =INT_GATE_TRIG, 1
r
w
=EXT_GATE_TRIG is Gate-/Trigger
signal
polarity of ext. Gate/Trigger signal
r
w
0 =high active/rising edge, 1 =low
active/falling edge
Effect of ext. Gate/Trigger signal
0 =Gate-/Count-Mode for
r
w
CLK_INPUT_SELECT =0/1,1
=Trigger-/Toggle-Mode for
Address:
58h
Attributes:
r
w
Address:
60h
Attributes:
(r) (w)