Siemens ERTEC 200P-2 Manual page 292

Enhanced real-time ethernet controller
Table of Contents

Advertisement

15dt14 EVENT2_CONTROL
16
EVENT2_INVERSION
31dt17 <reserved>
Register:
TIM_2_PRESCALER_REG
Bits:
31dt0
Description:
Bit
Identifier
7dt0
PRESCALER_VALUE
31dt8 <reserved>
Register:
TIM_2_LOAD_REG
Bits:
31dt0
Description:
Bit
Identifier
31dt0 LOAD_RELOAD_VALUE
Register:
TIM_2_COUNT_REG
Bits:
31dt0
Description:
Bit
Identifier
31dt0 COUNTER_VALUE
Register:
TIM_2_INT_EV_REG
Bits:
31dt0
Description:
Bit
Identifier
31dt0 INT_EVENT_VALUE
Register:
TIM_2_EXT_EV_1_REG
Bits:
31dt0
Copyright © Siemens AG 2016. All rights reserved
Technical data subject to change
0h
0h
0h
Reset value:
Timer PRESCALER Register for Timer 2
Reset
00h
000000h
Reset value:
Timer LOAD/RELOAD Register for Timer 2
Reset
00000000h r
Reset value:
Timer COUNT Register for Timer 2
Reset
00000000h r
Reset value:
Timer INT_EVENT Register for Timer 2
Reset
00000000h rh w Internal Event Value
Reset value:
292
0 =not inverted, 1 =inverted
Effect of EXT_EV2 on External Event
r
w
register
Inversion of Event2
r
w
0 =not inverted, 1 =inverted
not used
00000000h
Attr.
Function / Description
r
w Prescaler Value
not used
00000000h
Attr.
Function / Description
w Load/Reload value
00000000h
Attr.
Function / Description
Counter Value
00000000h
Attr.
Function / Description
00000000h
Address:
44h
Attributes:
(r) (w)
Address:
48h
Attributes:
r
w
Address:
4Ch
Attributes:
r
Address:
50h
Attributes:
r
w
Address:
54h
Attributes:
r
w
ERTEC 200P-2 Manual
Version 1.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ertec 200p

Table of Contents