Bit
Identifier
1dt0 PR_GPIO32
3dt2 PR_GPIO33
5dt4 PR_GPIO34
7dt6 PR_GPIO35
9dt8 PR_GPIO36
11dt1
PR_GPIO37
0
13dt1
PR_GPIO38
2
15dt1
PR_GPIO39
4
17dt1
PR_GPIO40
6
19dt1
PR_GPIO41
8
21dt2
PR_GPIO42
0
23dt2
PR_GPIO43
2
25dt2
PR_GPIO44
4
27dt2
PR_GPIO45
6
29dt2
PR_GPIO46
8
Copyright © Siemens AG 2016. All rights reserved
Technical data subject to change
the following coding
00 - highZ
01 - Pull-up
10 - highZ
11 - Pull-down
If the PAD is switched to output, the pull resistors are au-
tomatically deactivated
Reset value does not apply as the register is loaded in
accordance with the function set with CONFIG.
Reset
Attr. Function / Description
r
xh
w pull control GPIO32
h
r
xh
w pull control GPIO33
h
r
xh
w pull control GPIO34
h
r
xh
w pull control GPIO35
h
r
xh
w pull control GPIO36
h
r
xh
w pull control GPIO37
h
r
xh
w pull control GPIO38
h
r
xh
w pull control GPIO39
h
r
xh
w pull control GPIO40
h
r
xh
w pull control GPIO41
h
r
xh
w pull control GPIO42
h
r
xh
w pull control GPIO43
h
r
xh
w pull control GPIO44
h
r
xh
w pull control GPIO45
h
r
xh
w pull control GPIO46
h