Quality; Hard-Error Fit Rates; Soft-Error Fit Rates - Siemens ERTEC 200P-2 Manual

Enhanced real-time ethernet controller
Table of Contents

Advertisement

6

QUALITY

6.1 Hard-Error FIT rates

(Ea=0.7eV, C.L.=60%, 24h/10yrs)
Ten years operation FIT rate @125°C:
- 315 FIT (ERTEC-Die: 217FIT, PHY-Die: 98 FIT)

6.2 Soft-Error FIT rates

Double bit errors: The adjacent bits in single port RAMs are in different words, therefore
they can be corrected by ECC. Based on literature values and simulation results double bit
fails have a probability of 1/10
Soft error rate for the memories in the ERTEC 200P (alpha & neutron):
alpha
142 FIT
neutron
1)
factor to neutron 0m
x 1,0
300 FIT
total SER
1)
Location: NewYork, USA
Note:
The neutron factor for various difference heights can be calculated at the following WEB
link:
http://www.seutest.com/cgi-bin/FluxCalculator.cgi
Copyright © Siemens AG 2016. All rights reserved
Technical data subject to change
th
to 1/100
0m
2000m 2300m
747 FIT
933 FIT
x 5,26
x 6,57
905 FIT
1091 FIT
th
of single bit fails.
2500m
3000m
158 FIT
1077,8 FIT
1525,1 FIT
x 7,59
x 10,74
1235,8 FIT
1683,1 FIT
499
3500m
4000m
2121,5 FIT
2901 FIT
5171,6 FIT
x 14,94
x 20,43
x 36,42
2279,5 FIT
3059 FIT
5329,6 FIT
ERTEC 200P-2 Manual
Version 1.0
5000m

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ertec 200p

Table of Contents