Bit
Identifier
0dt0
SW_JOB_START
1dt1
JOB_EN
2dt2
HW_JOB_START_EN
3dt3
HW_FLOW_EN
4dt4
INTR_EN
5dt5
JOB_RESET
7dt6
<notused>
13dt8 HW_SELECT
15dt14 <notused>
20dt16 JOB_PRIO
23dt21 <notused>
31dt24 TRANSFER_PTR
Register:
GDMA_JOB2_CTRL
Bits:
31dt0
Description:
Bit
Identifier
0dt0
SW_JOB_START
1dt1
JOB_EN
2dt2
HW_JOB_START_EN
3dt3
HW_FLOW_EN
4dt4
INTR_EN
5dt5
JOB_RESET
Copyright © Siemens AG 2016. All rights reserved
Technical data subject to change
Reset
Attr.
0h
0h
r
0h
r
0h
r
0h
r
0h
r
0h
r
00h
r
0h
r
00h
r
0h
r
00h
r
Reset value:
Job Control Registers 2
Reset
Attr.
0h
0h
r
0h
r
0h
r
0h
r
0h
r
131
Function / Description
Start Job from SW
t
0 = don't care, 1 = Start
Job Enable
w
0 = disable, 1 = enable
Start Job by Hardware
w
0 = disable, 1 = enable
Hardware Triggered Flow Enable
w
0 = disabled, 1 = enabled
Interrupt Request Generation Enable
w
0 = disabled, 1 = enabled
Reset Job (cancel running job)
w
0 = don't care, 1 = Cancel
all bits = '0'
HW Job Start Selector (selects one from
w
64 inputs)
all bits = '0'
w
Job Priority (0-31)
all bits = '0'
First Transfer Number of Job in Trans-
w
fer List (0-255)
00000000h
Function / Description
Start Job from SW
t
0 = don't care, 1 = Start
Job Enable
w
0 = disable, 1 = enable
Start Job by Hardware
w
0 = disable, 1 = enable
Hardware Triggered Flow Enable
w
0 = disabled, 1 = enabled
Interrupt Request Generation Enable
w
0 = disabled, 1 = enabled
Reset Job (cancel running job)
w
0 = don't care, 1 = Cancel
Address:
18h
Attributes:
(r)
(w)(t)
ERTEC 200P-2 Manual
Version 1.0