IRQ
Interrupt Name
no.
13
INT_SPI1
14
INT_SPI1_Overr
un
15
INT_SPI2
16
INT_SPI2_Overr
un
17
INT_SPI_ParityE
RR
18
Reserved
19
Reserved
20
Reserved
21
INT_TIMER0
22
INT_TIMER1
23
INT_TIMER2
24
INT_TIMER3
25
INT_TIMER4
26
INT_TIMER5
27
WD_INT_ARM9
26
28
SPI1_TFE
Copyright © Siemens AG 2016. All rights reserved
Technical data subject to change
Ty-
Signal
pe
LT
SPI1_SSPINTR
(group interrupt)
SPI1_SSPRORIN
LT
TR
(Error interrupt)
LT
SPI2_SSPINTR
(group interrupt)
SPI2_SSPRORIN
LT
TR
(Error interrupt)
ET/
SPI_PARITY_ER
R
R
-----
-----
-----
*)
TIM_OUT0
*)
TIM_OUT1
*)
TIM_OUT2
*)
TIM_OUT3
*)
TIM_OUT4
*)
TIM_OUT5
ET/
Watchdog
R
ARM926
LT
SPI1_TFE
64
Cause
Transmit FIFO empty
Transmit FIFO half-empty or
empty
Transmit FIFO not full
Receive FIFO not empty
Receive FIFO half-full or full
Receive FIFO overrun
Overrun Error Interrupt
Transmit FIFO empty
Transmit FIFO half-empty or
empty
Transmit FIFO not full
Receive FIFO not empty
Receive FIFO half-full or full
Receive FIFO overrun
Overrun Error Interrupt
Interrupt for
SPI1/2_PARITY_ERR
Timer expired (value 0
reached)
Timer expired (value 0
reached)
Timer expired (value 0
reached)
Timer expired (value 0
reached)
Timer expired (value 0
reached)
Timer expired (value 0
reached)
ARM926 Watchdog Inter-
rupt
Transmit FIFO empty
Interrupt
source
SPI1, 2
TIMER
WD
SPI1, 2