Pll Wiring (Power Supply); Figure 53: Recommended For Pll Power Supply Filter - Siemens ERTEC 200P-2 Manual

Enhanced real-time ethernet controller
Table of Contents

Advertisement

4.3 PLL Wiring (Power Supply)

Since GND noise may affect VDD through C1 and C2, GND must be stable.

Figure 53: Recommended for PLL Power Supply Filter

Dimensioning the PLL Power Supply Filter
R
R
C
C
L
1
2
(
damping
factor)
2
L
1
f
(cut
off
frequency
in
Hz)
0
2
L
(
C
C
)
1
2
where R+R
0.8
, C
10 µF,
0.7 (should not be less than 0.7 to decrease the
L
2
sensitivity for resonance), f
<= 5kHz
0
Example:
With R+R
= 0.8
, L = 22 µH, C
= 68 µF, C
= 0.3 µF (ceramic capacitor) this results in f
L
2
1
0
= 4.1 kHz and
= 0.70.
C
should be an SMD capacitor (e.g. ceramic 300 nF) for elimination of high frequency
1
components. Be sure to place it as close as possible to a power supply pin.
Copyright © Siemens AG 2016. All rights reserved
479
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ertec 200p

Table of Contents