2.3.4.5 Register Description

A description of the registers can be found in the specifications: /55/.
Note: The "notused" register bits can also be written, unlike in the IP specifications.
The data-bus-width of all specified registers in this module is: 32.
A '0' is read from Software for each not specified Bit in the registers.
The addressing is organized: WORD - wise
Module: /gdma
Register:
GDMA_REG_ADDR
Bits:
31dt0
Description:
Bit
Identifier
3dt0
<notused>
31dt4 REG_ADDR
Register:
GDMA_LIST_ADDR
Bits:
31dt0
Description:
Bit
Identifier
3dt0
<notused>
31dt4 LIST_ADDR
Register:
GDMA_MAIN_CTRL
Bits:
31dt0
Description:
Bit
Identifier
0dt0
DMA_EN
1dt1
SW_RESET
14dt2 <notused>
15dt15 JC_RESET
16dt16 ERR_INT_EN
Copyright © Siemens AG 2016. All rights reserved
Technical data subject to change
Reset value:
GDMA Register Base Address
Reset
Attr.
0h
r
0000000h r
Reset value:
DMA Transfer List Base Address
Reset
Attr.
0h
r
0000000h r
Reset value:
Main Control register
Reset
Attr.
0h
r
0h
r
00h
r
0h
r
0h
r
129
00000000h
Function / Description
all bits = '0'
w
DMA Register Base Address
00000000h
Function / Description
all bits = '0'
w
DMA Transfer List Base Address
00000000h
Function / Description
w
Global Enable
Software Reset
w
'0' = don't care, '1' = Reset
all bits = '0'
Reset Job Counter
w
'0' = don't care, '1' = Reset
w
Error Interrupt Enable