power-off
c e
Syntax
Parameters
Defaults
Command Modes
Command
History
98
|
Control and Monitoring
When you enter the ping command without specifying an IP/IPv6 address (Extended Ping), you are
prompted for a target IP/IPv6 address, a repeat count, a datagram size (up to 1500 bytes), a timeout in
seconds, and for Extended Commands. See
that return from a ping command.
Figure 5-8. Command Example: ping (IPv4)
FTOS#ping 172.31.1.255
Type Ctrl-C to abort.
Sending 5, 100-byte ICMP Echos to 172.31.1.255, timeout is 2 seconds:
Reply to request 1 from 172.31.1.208
Reply to request 1 from 172.31.1.216
Reply to request 1 from 172.31.1.205
:
:
Reply to request 5 from 172.31.1.209
Reply to request 5 from 172.31.1.66
Reply to request 5 from 172.31.1.87
FTOS#
Figure 5-9. Command Example: ping (IPv6)
FTOS#ping 100::1
Type Ctrl-C to abort.
Sending 5, 100-byte ICMP Echos to 100::1, timeout is 2 seconds:
!!!!!
Success rate is 100.0 percent (5/5), round-trip min/avg/max = 0/0/0 (ms)
FTOS#
Turn off power to a selected line card or the standby (extra) Switch Fabric Module (SFM).
power-off {linecard number | sfm sfm-slot-id}
linecard number
Enter the keyword
C-Series Range: 0 to 7
E-Series Range: 0 to 13 on a E1200/E1200i, 0 to 6 on a E600/E600i, and 0 to 5 on a
E300.
sfm sfm-slot-id
Enter the keyword
off power.
Note: This option is supported on E-Series only.
Disabled
EXEC Privilege
Version 8.1.1.2
Introduced on E-Series ExaScale E600i
Version 8.1.1.0
Introduced on E-Series ExaScale E1200i
Version 7.5.1.0
Introduced on C-Series