Command
History
Example
Related
Commands
show interfaces status
c e s
Syntax
Parameters
Defaults
604
|
Interfaces
Version 7.6.1.0
Introduced for S-Series only
Figure 23-37. show interfaces status Command Example
FTOS#show interfaces stack-unit 0
GigabitEthernet 0/1 is down, line protocol is down
Hardware is Force10Eth, address is 00:01:e8:4c:f2:82
Current address is 00:01:e8:4c:f2:82
Pluggable media not present
Interface index is 34129154
Internet address is not set
MTU 1554 bytes, IP MTU 1500 bytes
LineSpeed auto, Mode auto
ARP type: ARPA, ARP Timeout 04:00:00
Last clearing of "show interface" counters 3w0d17h
Queueing strategy: fifo
Input Statistics:
0 packets, 0 bytes
5144 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts
0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts
0 Multicasts, 0 Broadcasts
0 runts, 0 giants, 0 throttles
0 CRC, 0 overrun, 0 discarded
Output Statistics:
0 packets, 0 bytes, 0 underruns
0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts
0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts
0 Multicasts, 0 Broadcasts, 0 Unicasts
0 throttles, 0 discarded, 0 collisions
Rate info (interval 299 seconds):
Input 00.00 Mbits/sec,
Output 00.00 Mbits/sec,
Time since last interface status change: 3w0d17h
GigabitEthernet 0/2 is down, line protocol is down
Hardware is Force10Eth, address is 00:01:e8:4c:f2:83
Current address is 00:01:e8:4c:f2:83
!-------------output truncated ----------------!
show hardware stack-unit
show interfaces
Display a summary of interface information or specify a line card slot and interface to display status
information on that specific interface only.
show interfaces [interface | linecard slot-number] status
interface
linecard slot-number
No default behavior or values
0 packets/sec, 0.00% of line-rate
0 packets/sec, 0.00% of line-rate
Display data plane and management plane input/output statistics.
Display information on a specific physical interface or virtual interface.
(OPTIONAL) Enter one of the following keywords and slot/port or number
information:
For a 1-Gigabit Ethernet interface, enter the keyword
followed by the slot/port information.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
(OPTIONAL) Enter the keyword
C-Series Range: 0 to 7 for C300; 0–3 for C150
E-Series Range: 0 to 13 on the E1200, 0 to 6 on the E600, 0 to 5 on the E300
GigabitEthernet
followed by the slot/port information.
linecard
followed by the slot number.