Left Limit ← Marker Peak List
Opens an edit dialog box to enter a value for the lower limit (left vertical line: S1 for
span > 0; T1 for zero span). The search is performed between the lines of the left and
right limit (see also
Remote command:
CALCulate<n>:MARKer<m>:X:SLIMits:LEFT
Right Limit ← Marker Peak List
Opens an edit dialog box to enter a value for the upper limit (left vertical line: S2 for
span > 0; T2 for zero span). The search is performed between the lines of the left and
right limit (see also
the stop frequency.
Remote command:
CALCulate<n>:MARKer<m>:X:SLIMits:RIGHT
Threshold ← Marker Peak List
Opens an edit dialog box to define the threshold line. The threshold line represents the
lower level limit for a "Peak" search and the upper level limit for a "Min" search.
Remote command:
CALCulate<n>:THReshold:STATe
CALCulate<n>:THReshold
ASCII File Export ← Marker Peak List
Opens the "ASCII File Export Name" dialog box and saves the active peak list in ASCII
format to the specified file and directory.
The file consists of the header containing important scaling parameters and a data sec-
tion containing the marker data. For details on an ASCII file see
File Export
This format can be processed by spreadsheet calculation programs, e.g. MS-Excel. It
is necessary to define ';' as a separator for the data import. Different language versions
of evaluation programs may require a different handling of the decimal point. It is there-
fore possible to select between separators '.' (decimal point) and ',' (comma) using the
"Decim Sep" softkey (see
Remote command:
FORMat:DEXPort:DSEParator
MMEMory:STORe<n>:LIST
Decim Sep ← Marker Peak List
Selects the decimal separator with floating-point numerals for the ASCII Trace export
to support evaluation programs (e.g. MS-Excel) in different languages. The values '.'
(decimal point) and ',' (comma) can be set.
Remote command:
FORMat:DEXPort:DSEParator
Marker Number ← Marker Peak List
If enabled, the determined peaks are indicated by their corresponding marker number
in the trace display.
Operating Manual 1176.7561.02 ─ 06

Right Limit

softkey).

Left Limit

softkey). If no value is set, the upper limit corresponds to
on page 96
Format",
on page 23.

"Decim Sep"

on page 183
FM Stereo Option R&S FSV–K7S
Instrument Functions FM Stereo (R&S FSV–K7S)
on page 106
on page 106
on page 97
on page 63).
on page 185
on page 185
Chapter 2.1.11, "ASCII
226

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsv-k7s

Table of Contents