Remote command:
Remote commands for the R&S DigIConf software always begin with SOURce:EBOX.
Such commands are passed on from the R&S FSVA/FSV to the R&S DigIConf auto-
matically which then configures the R&S EX-IQ-BOX via the USB connection.
All remote commands available for configuration via the R&S DigIConf software are
described in the "R&S®EX-IQ-BOX Digital Interface Module R&S®DigIConf Software
Operating Manual".
Example 1:
SOURce:EBOX:*RST
SOURce:EBOX:*IDN?
Result:
"Rohde&Schwarz,DigIConf,02.05.436 Build 47"
Example 2:
SOURce:EBOX:USER:CLOCk:REFerence:FREQuency 5MHZ
Defines the frequency value of the reference clock.
Digital IQ Info
Displays a dialog box with information on the digital I/Q input and output connection via
the optional R&S Digital I/Q Interface (R&S FSV-B17), if available. The information
includes:
Device identification
Used port
(Maximum) digital input/output sample rates and maximum digital input/output
transfer rates
Status of the connection protocol
Status of the PRBS descewing test
For details see "Interface Status Information" in "Instrument Functions - R&S Digital I/Q
Interface (Option R&S FSV-B17)" in the description of the base unit.