R&S FSV-K7 Operating Manual page 70

Analog demodulation and fm stereo
Table of Contents

Advertisement

®
R&S
FSV-K7/K7S
Remote command:
CALCulate<n>:MARKer<m>:AOFF
Marker Table
Defines how the marker information is displayed.
For more information, see "Displayed Marker Information" in the description of the
base unit.
"On"
"Off"
"Aut"
Remote command:
DISPlay:MTABle
Marker Stepsize
Opens a submenu to set the step size of all markers and delta markers.
Default value for the marker step size is
Stepsize Standard ← Marker Stepsize
Moves the marker or delta marker from one measurement point to the next, if the
marker or delta marker value is changed via the rotary knob ( "Marker 1 / Marker 2 /
Marker 3 / ... Marker 16,/ Marker Norm/Delta" softkeys, see
Marker 3 / ... Marker 16,/ Marker Norm/Delta"
than measurement points exist, it is not possible to read out all measured values. In
this case, use the
Remote command:
CALC:MARK:X:SSIZ STAN (see
on page 107)
Stepsize Sweep Points ← Marker Stepsize
Moves the marker or delta marker from one measured value to the next, if the marker
or delta marker value is changed via the rotary knob ( "Marker 1 / Marker 2 / Marker 3 /
... Marker 16,/ Marker Norm/Delta" softkeys, see
Marker 16,/ Marker Norm/Delta"
ment points exist, every single measured value is accessible and its value is displayed
in the marker field.
The number of measured values is defined in the ""Sweep"" menu via the
Points
This functionality is available for all base unit measurements with the exception of sta-
tistics ( "APD" and "CCDF" softkeys in the "Measurement" menu).
Remote command:
CALC:MARK:X:SSIZ POIN (see
on page 107)
Operating Manual 1176.7561.02 ─ 06
Displays the marker information in a table in a separate area beneath
the diagram.
Displays the marker information within the diagram area.
(Default) The marker table is displayed automatically if more than 2
markers are active, and removed if only 1 or 2 markers are active.
This helps keep the information in the display clear.
on page 109
Stepsize Sweep Points
softkey.
Analog Demodulation Option R&S FSV–K7
Softkeys of the Analog Demodulation option
on page 98
Stepsize Sweep
on page 68). If more measured values
softkey.
CALCulate<n>:MARKer<m>:X:SSIZe
"Marker 1 / Marker 2 / Marker 3 / ...
on page 68). If more measured values than measure-
CALCulate<n>:MARKer<m>:X:SSIZe
Points.
"Marker 1 / Marker 2 /
Sweep
70

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsv-k7s

Table of Contents