R&S FSV-K7 Operating Manual page 120

Analog demodulation and fm stereo
Table of Contents

Advertisement

®
R&S
FSV-K7/K7S
[SENSe:]ADEMod:SPECtrum:BANDwidth|BWIDth[:RESolution]
[SENSe:]ADEMod:SPECtrum:RESult
[SENSe:]ADEMod:SPECtrum:SPAN[:MAXimum]
[SENSe:]ADEMod:SPECtrum:SPAN:ZOOM
[SENSe:]ADEMod:SQUelch[:STATe]
[SENSe:]ADEMod:SQUelch:LEVel
[SENSe:]ADEMod:SRATe?
[SENSe:]ADEMod<n>:ZOOM[:STATe]
[SENSe:]ADEMod<n>:ZOOM:STARt
[SENSe:]ADEMod<n>:ZOOM:LENGth
[SENSe:]ADEMod<n>:ZOOM:LENGth:MODE
[SENSe:]ADEMod:CAPTure:DOFFset <Time>
This command defines an offset of the defined measurement time from the beginning
of the capture buffer for analog demodulation if
is set to manual mode.
All results are recalculated automatically based on the new data.
Parameters:
<Time>
Example:
Mode:
Manual operation:
[SENSe:]ADEMod:CAPTure:TIME <Time>
This command defines the size of the capture buffer for analog demodulation if
[SENSe:]ADEMod:CAPTure[:MODE]
Parameters:
<Time>
Example:
Mode:
Manual operation:
Operating Manual 1176.7561.02 ─ 06
Analog Demodulation Option R&S FSV–K7
Remote Commands of the Analog Demodulation (R&S FSV–K7)
...............................................................................140
...............................................................141
......................................................................142
................................................................................ 142
...................................................................................142
............................................................................................. 143
..............................................................................143
................................................................................144
............................................................................. 144
...................................................................145
*RST:
0
ADEM:CAPT MAN
Activates the manual capture buffer processing mode.
ADEM:CAPT:TIME 500 us
Sets the size of the capture buffer to 500 us.
ADEM:CAPT:DOFF 10us
Results are recalculated for the data in the capture buffer start-
ing at 10us.
ADEMOD
See
"Demod Offset"
on page 57
is set to manual mode.
Range:
0 to 7.5 MSamples (time depends on DBW)
*RST:
62.5us
ADEM:CAPT MAN
Activates the manual capture buffer processing mode.
ADEM:CAPT:TIME 500 us
ADEMOD
See
"Capture Time"
on page 57
......................................... 140
[SENSe:]ADEMod:CAPTure[:MODE]
120