Removing 3.5-Inch Hdd Modules; Preliminary Steps - Fujitsu PRIMERGY RX2540 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2540 M4:
Table of Contents

Advertisement

7.3.6

Removing 3.5-inch HDD modules

Customer Replaceable Unit
(CRU)
Tools: tool-less
7.3.6.1

Preliminary steps

Ê If the HDD module to be removed is combined into a RAID array, proceed
as follows:
RAID level
RAID 0
RAID 1
RAID 5
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V
CAUTION!
All data on all HDDs in the array will be lost when deleting the RAID
array. Be sure to back up your data before deleting a RAID array.
For more information, see the "ServerView Suite RAID Management"
user guide.
RX2540 M4
Hard disk drives (HDD) and solid state drives (SSD)
Procedure
V
CAUTION!
RAID 0 provides no data redundancy.
In case of an HDD module is defect, all data
are lost!
Removing an HDD module from a RAID 1 or RAID 5
array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild
will be performed as a background process,
see section
on page
Upgrade and Maintenance Manual
Hardware: 5 minutes
"Performing a RAID array rebuild"
113.
151

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents