Advertisement

Expansion cards and backup units
9.4.1

Installing an OCP module

Upgrade and Repair Unit
(URU)
Tool:
Phillips PH1 / (+) No. 1 screw driver
9.4.1.1

Preliminary steps

"Shutting down the server" on page 55
Ê
"Disconnecting the power cord" on page 56
Ê
"Getting access to the component" on page 58
Ê
Ê If applicable, remove the riser module 1, see section
modules" on page
9.4.1.2

Removing the dummy cover

Figure 160: Removing the dummy cover
Ê Grip the handle and pull out the dummy cover.
V
CAUTION!
Keep the dummy cover for future use. If an OCP module is removed and
not immediately replaced by a new one, a dummy cover must be
reinstalled in the bay to comply with applicable EMC regulations and
satisfy cooling requirements.