Resetting The Error Status After Replacing Memory Modules Or Cpus; Memory Modules - Fujitsu PRIMERGY RX2540 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2540 M4:
Table of Contents

Advertisement

Basic software procedures
Ê Under Reboot Retries, specify the maximum number of boot attempts (0 to
7) in the Default for reboot tries field.
Resetting the boot retry counter using iRMC web interface
Ê Enter the ServerView iRMC web interface.
Ê Select the Server Management menu.
Ê The following boot retry counter settings are available under ASR&R
Options:
Ê Under Retry counter max specify the maximum number of attempts to
boot the operating system (0 to 7).
Ê Under Retry counter the current number of remaining boot attempts is
displayed. Overwrite this value with the maximum number of boot
attempts specified above in order to reset the boot retry counter.
Ê Click Apply for the changes to take effect.
I
For more information on iRMC settings, see the iRMC user guides.
5.2.7
Resetting the error status after replacing memory
modules or CPUs
5.2.7.1

Memory modules

ServerView Operations Manager may report a defective memory module in
case of a memory error.
I
Important note
After replacing a defective memory module, please check if the error
counter has been reset automatically. If the memory slot is still marked
as failed, please reset the error counter manually using one of the
methods below.
104
Upgrade and Maintenance Manual
RX2540 M4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents