Advertisement

9.11

Flash Backup unit (FBU)

The FBU backs up the memory contents of the RAID controller in the event of
a power failure. You can install up to two FBUs.
Depending on the installed riser card holder the installation in the FBU holder
and the position for the FBU holder are different.
– If no riser card holder or a a riser card holder HL is installed: The position for
the FBU is on the air duct.
– If a riser card holder FL is installed: The position for the FBU is on the riser
card holder.
9.11.1 Replacing a TFM
Upgrade and Repair Unit
(URU)
Tools: Phillips PH1 / (+) No. 1 screw driver
9.11.1.1 Preliminary steps
"Locating the defective server" on page 53
Ê
"Shutting down the server" on page 55
Ê
"Disconnecting the power cord" on page 56
Ê
"Getting access to the component" on page 58
Ê
9.11.1.2 Removing the defective TFM
Ê Remove the expansion card with the defective TFM installed, see section
"Removing an expansion card" on page
RX2540 M4
Upgrade and Maintenance Manual
Expansion cards and backup units
Hardware: 10 minutes
263.
309