Upgrading The Main Memory - Fujitsu PRIMERGY RX2540 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2540 M4:
Table of Contents

Advertisement

Processor (CPU)
Figure 236: Installing the heat sink
Ê Carefully seat the heat sink onto the CPU socket.
I
Take care of the pins. There is only one position which fits.
Ê Fasten the four captive screws in the sequence printed on the heat sink
(1 to 4) by hand, by proceeding as follows:
Torque: 1.4 Nm (not used in Japan)
Ê At first, fasten the captive screws 1 and 2 completely.
Ê Fasten the captive screws 3 and 4 completely.

11.2.4 Upgrading the main memory

Ê Select an adequate memory configuration for "2 CPUs populated", see
section
"Basic information" on page
Ê Install memory modules, see section
page
339.
11.2.5 Concluding steps
"Installing the air duct" on page 89
Ê
354
Upgrade and Maintenance Manual
328.
"Installing a memory module" on
RX2540 M4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents