Alteon Application Switch Operating System Application Guide
Port Teaming
In some cases when the ports and trunks are operationally enabled, some of the other ports or
trunks in the team are not operational either because of a link going down, or because they were
operationally disabled or were set as disabled. If this happens, the team goes into off mode. In this
mode, the team waits until all ports or trunks are operational before going back to passive mode to
repeat the cycle.