9. On Alteon, apply and verify the configuration.
>> Filter 1 Advanced# apply
>> Filter 1 Advanced# /cfg/bwm/cur
Examine the resulting information. If any settings are incorrect, make the appropriate changes.
10. On Alteon, save your new configuration changes.
>> Bandwidth Management# save
11. On Alteon, check the BWM information.
>> Bandwidth Management# /info/bwm <contract number>
Check that all BWM contract parameters are set correctly. If necessary, make any appropriate
configuration changes and then check the information again.
Example
Configuring Time and Day Policies
Bandwidth Management contracts can be configured to have different limits depending on the time
of day and day of the week. For example, in office networks that are typically busy during a
workday, higher bandwidth limits can be applied during peak work hours. Lower bandwidth limits
can be applied during hours with minimal traffic, such as on evenings or weekends.
Up to two time policies can be applied to each contract. The default settings for each time policy are:
"
Day everyday, From Hour 12am, To Hour 12am, Policy 512, time policy
"
disabled
If both Time Policy 1 and Time Policy 2 are enabled on a contract, and both policies match the
current time set in Alteon's system clock, Time Policy 1 will take effect.
Note:
When configuring time policies, the "To" hour cannot be earlier than the "From" hour, as in a
time policy set from 7PM to 7AM. Alteon does not calculate time policies that cross the 24-hour day
boundary.
1. Configure three BWM policies for high, low, and default bandwidth. These policies will be applied
to different time policies in
>> /cfg/bwm/policy 1/hard 10M/soft 5M
>> /cfg/bwm/policy 1/hard 5M/soft 1M
>> /cfg/bwm/policy 3/hard 4M/soft 2M
2. Create a BWM contract that will contain the time policies.
>> /cfg/bwm/cont 1
Document ID: RDWR-ALOS-V2900_AG1302
Alteon Application Switch Operating System Application Guide