asieps_tobira.book 21 ページ 2009年10月26日 月曜日 午前9時16分
10) Connect the ATF cooler hoses. (AT model)
11) Connect the radiator outlet hose.
12) Connect the radiator main fan motor connector
(A) and sub fan motor connector (B).
(A)
13) Install the radiator under cover.
14) Install the under cover.
15) Lower the vehicle.
Radiator
CO-00253
CO-00270
CO-02097
(B)
CO-00275
CO(H4SO)-21
16) Connect the battery ground cable to the bat-
tery.
17) Fill engine coolant. <Ref. to CO(H4SO)-12,
FILLING OF ENGINE COOLANT, REPLACE-
MENT, Engine Coolant.>
18) Check the ATF level. <Ref. to 4AT-26, IN-
SPECTION, Automatic Transmission Fluid.>
C: INSPECTION
1) Remove the radiator cap, fill the radiator with en-
gine coolant, and then install the tester to the instal-
lation position of cap.
2) In the following cases, apply a pressure of 157
2
kPa (1.6 kg/cm
, 23 psi) to the radiator.
• There is coolant leaking from the radiator or its
vicinity.
• There is coolant leaking from the hoses or con-
nections.
CAUTION:
• Engine should be turned off.
• Wipe engine coolant from check points in ad-
vance.
• Be careful of engine coolant from spurting
out when removing the tester.
• Be careful not to deform the filler neck of ra-
diator when installing and removing the tester.