4−54
Installation and Maintenance Volume

External Alarm Port

The external alarm port uses a 9-pin DB9 female connector with the following pin arrangement:
Use connector J3 for the Octel 200.
-
Use connector J5 for the Octel 300.
-
The external-alarm connector pin assignments are as follows:
AJ1 and AJ2 Connector Pin Assignments
Pin Number
Relay A is the major alarm relay. Relay B is the minor alarm relay. A relay is open when there is no
alarm. When a relay is closed, it indicates an alarm condition.
With power removed from the cabinet, both Relay A and Relay B are in the closed position (normally
closed), indicating an alarm condition.
Pins 3 and 8 are linked together to provide a loop. You can use this as a confirmation that an alarm cable
is installed. Pins 4, 5, and 9 are connected to cabinet ground. These pins can be jumpered to a relay
contact, if closure to ground is required.
Both Relay A and Relay B are rated at
48 Vdc maximum
-
0.5 A maximum
-
The link loop is rated at
12 Vdc maximum
-
200 mA maximum
-
Octel 200/300
S.4.1
S
S
S
5
S
S
S
9
Front View DB9 Male Connector
Signal Function
1
Relay A, Pin 1
2
Relay B, Pin 1
3
LINK
4
GND
5
GND
6
Relay A, Pin 2
7
Relay B, Pin 2
8
LINK
9
GND
S
S
1
S
6
PB60019−01